To Enable DesignState Processing for Selected Individual isos/pipelines

Create a new workset and associate to a CONNECTED Project and SetUp to PlantSight iModel.
  1. Launch OpenPlant Isometrics Manager with the CONNECTED workset.
  2. Define Pipeline and place them.
  3. Create Isosheet using Pipeline Manager .
  4. Check-in all the components to PlantSight. All the components are posted to the PlantSight.
  5. In the <Workset>\Standards\OpenPlant\OpenPlant.cfg, define the OP_DESIGNSTATES_FILE = $(OPENPLANT_WORKSET_STANDARDS)ApplicationDb/DesignStates.json and save the file.
  6. Launch OpenPlant Isometrics Manager with the CONNECTED workset.
  7. Select the Connect icon on the PlantSight tab. The PlantSight iModel is loaded in OpenPlant Isometrics Manager.
  8. Generate Isometrics for both the isosheets. Right-click on an isosheet, the "Set Design State to" option gets enabled.
All the component Design State is updated in the output in PlantSight iModel Hub.